What Is The Main Earth Block?

Publish Time: Author: Site Editor Visit: 8

Main earth block: the "life hub" of electrical safety

In complex electrical systems, the main earth block acts as an invisible safety guard, bearing the responsibility of safeguarding life and equipment safety. This seemingly inconspicuous metal component is essentially the "nerve center" of the grounding system, tightly connecting the metal casing and frame of the equipment to the ground, and building a crucial safety protection net.

Three core functions

Electric shock protection barrier: When the insulation of the equipment is damaged, the leakage current is introduced into the ground through the main earth block, forming a short circuit to trigger the action of the protection device, avoiding electric shock accidents caused by human contact with the live shell.

Lightning discharge channel: As a key node in the lightning protection grounding system, the main earth block provides a low impedance path for lightning current, safely guiding hundreds of thousands of volts of lightning voltage into the ground to protect equipment from lightning damage.

Electromagnetic interference filtering: In precision electronic systems, the main earth block eliminates potential differences through equipotential connections, effectively suppressing high-frequency electromagnetic interference and ensuring stable equipment operation.

Technical feature analysis

The main earth block is usually made of highly conductive copper or copper alloy, with tin or nickel plating on the surface to enhance its oxidation resistance. Its typical structure includes:

Terminal post: using M8-M12 standard thread to ensure reliable crimping of multiple grounding wires

Identification system: prominent grounding symbol (⏚) and rated current value (such as 250A)

Protective design: equipped with anti loosening gaskets and insulation covers to prevent accidental contact and mechanical damage

Key points of installation specifications

According to the IEC60364 standard, the cross-sectional area of the main earth block should match the grounding conductor, and the minimum cross-sectional area requirement for copper terminals is:

Distribution box total incoming line ≤ 160A: ≥ 6mm²

Distribution box total incoming line > 160A: ≥ 10mm²

During installation, it is necessary to ensure that the terminals are directly connected to the grounding main line. It is strictly prohibited to connect multiple devices in series before grounding to ensure the independence and reliability of the grounding system.

This seemingly simple metal component is actually a crucial link in the electrical safety chain. From household distribution boxes to industrial substations, every electrical system cannot do without its silent protection, like an invisible safety line, always ready to introduce dangerous currents into the earth and safeguard the electric world of human civilization.