The short-circuit withstand capacity requirement of the lighting electrical ready board is an important indicator to ensure its safe and stable operation. The following is a detailed explanation of the short-circuit withstand capacity requirements for lighting electrical ready boards:

Firstly, the lighting electrical ready board needs to be able to withstand a certain short-circuit current. Short circuit fault refers to the short circuit between current carrying conductors, including phase to phase short circuit and short circuit between phase line and neutral line. Short circuit fault can cause a sharp increase in current in the circuit. Therefore, the electrical ready board must be able to withstand the thermal and electrical stresses generated by this short-circuit current without damage or failure.

Secondly, the short-circuit withstand capacity of the electrical ready board is usually reflected by its short-circuit capacity. Short circuit capacity refers to the ability of a electrical ready board to withstand overload current or short-circuit current, generally marked as KA value. Common short-circuit capacities include 6KA, 10KA, 16KA, etc., which need to be selected according to the load current and environment. The larger the short-circuit capacity, the stronger the short-circuit bearing capacity of the electrical ready board.

In addition, in order to ensure that the electrical ready board can quickly cut off the circuit in the event of a short circuit fault and prevent the fault from expanding, the electrical ready board is usually equipped with short circuit protection devices such as fuses or low-voltage circuit breakers. These protective appliances need to have sufficient breaking capacity to quickly cut off the circuit in the event of a short circuit fault, protecting the safety of electrical ready boards and other equipment.

In summary, the short-circuit withstand capacity requirement of lighting electrical ready boards is an important guarantee for their safe and stable operation. By selecting appropriate short-circuit capacity and equipping sufficient short-circuit protection devices, it is possible to ensure that the electrical ready board can quickly cut off the circuit in the event of a short-circuit fault, prevent the fault from expanding, and ensure the safe and stable operation of the power system.