Publish Time: Author: Site Editor Visit: 579

Wire connector can be divided into: 102 two wire combination, 104 four wire combination and 106 six wire combination, which are mainly hard wire. The wire can be peeled 10-12mm long and then inserted. The relevant data are as follows: the number of poles is 4, the minimum cross-sectional area of the connecting wire [mm?] 0,75-2, 5 mm? Minimum connectable conductor cross section [AWG] 18-12 AWG applicable wire type E connection mode push wire? Minimum connectable conductor cross section area [mm?] 1,5-2,5 mm? Minimum accessible conductor cross section [AWG] 16-12 AWG connection mode push wire? Rated voltage en 400 V, withstand instantaneous peak voltage 4 kV pollution level 2 rated current en 24 a weight 2, 677 g color orange connecting wire quantity 4 potential quantity 1 height 13 mm height 0516 in thickness 13 mm thickness 0512 in width 19 5 mm width 0768 in minimum stripping length 12 mm maximum stripping length 12 mm stripping length 0,47 in customs tariff No. 85369010 country of origin Deutschland kv222 universal wire connector is divided into: 412 two wire combination, 413 three wire combination, 415 five wire combination The product has strong usability. It is widely used for the connection of soft or hard wires of about 0.05-2.5 square meters. It is widely used in decoration and wiring, electrical connection, lamp connection and so on. Usage: peel the wire 10-12 mm, pull the orange wrench to 90 degrees, insert the peeled wire, and then put the wrench down to clamp it. The relevant receipts are as follows: RoHS compliant project team 7 (Installation Technology) minimum connectable conductor cross-sectional area [mm?] 0,08-2,5 mm? Minimum connectable conductor cross-section [AWG] 28-14 AWG applicable conductor type E + F connection mode cage clamp? Connection minimum connectable conductor sectional area [mm?] 0, 08-4 mm? Minimum connectable conductor cross-sectional area [AWG] 28-12 AWG applicable wire type F rated voltage en 400 V withstand instantaneous peak voltage 4 kV pollution level 2 rated current en 32 a weight 4153 g color gray wiring direction side wiring number 3 potential number 1 height 14,5 mm height 0571 in thickness 17 mm thickness 0669 in width 20,5 mm width 0, 807 in, the minimum stripping length is 9 mm, the maximum stripping length is 10 mm, and the stripping length is 0, 37 in Kv224-101 this product is aimed at the butt joint of hard wire and flexible wire within 2.5 square meter. After stripping the hard wire for 8-12 mm, insert it directly into the circular wiring hole, and then peel the flexible wire or hard wire or multi strand wire for 8-12 mm. Pick up the connector and press it up and down, then insert the multi strand wire into the square wiring hole, and then release it to complete the wiring. The relevant data are as follows: Electrical performance reference standard UL IEC rated voltage 300V 450V rated current 22a 24a wire diameter 22-12awg 0.2-2.5mm2 withstand voltage ac2500v / 1min mechanical properties ambient temperature - 40 ° C ~ + 105 ° C stripping length 9-11mm dimension spacing 8.0mm (. 315 ") pole number 1p material and electroplated plastic parts PA66, UL94V-0 shrapnel stainless steel contact material is phosphor bronze kv773-173. This product is used for 4-6m2 wiring, which is combined with three wires. For single strand hard wire or multi strand hard wire connection, the wiring can be completed by peeling 10-12mm and inserting into the wiring hole. The relevant data are as follows: kv773-173 electrical performance reference standard UL IEC rated voltage 300V 450V rated current 30A 35A wire diameter 22-12awg 0.75-6mm2 withstand voltage ac2500v / 1min mechanical properties ambient temperature - 40 ° C ~ + 105 ° C stripping length 8-10mm size 20.1 × 25.6 × 14.2 (mm) spacing 3.5mm, 3P material and electroplated plastic parts PA66, UL94V-0 spring sheet stainless steel contact material copper

Next Usage And Advantages Of Wire Connector Terminals For Decoration And Wiring